Question:
Hi,
we want to extract variant configuration data, so we have defined a datasource based on 2LIS_11_VAITM and VBPS with CTBW.
Then created infosource in BW and tested via full-upload -> BW got data and it is correct.
Now we tried delta-init (ok) and delta-update but never get any update records for existing orders and also no new records based on new orders for configuration datasource.
In other words: Delta-mode for 2LIS_11_VAITM is ok but delta-mode for the datasource which was generated by CTBW doesn't deliver anything.
Any helpfull hints?
Thanks
Answer:
maybe too basic as an answer, but did you run the V3 update ?
2LIS_11 lies in the scope of LO-COCKPIT
Ch
Answer:
In LO-Cockpit we have set 'direct delta' and not 'v3-update' for application 11.
Do we need to change this?
thanks