No data in field with INIT (but filled in RSA3) !

Question: we enhanced the 2LIS_13_VDITM with a field, wrote the code to fill it in the ZXRSAU01, filled the setup tables and tested it in RSA3 : everything looks ok (the new field is filled).
However when we extract data with an init infopackage, all data comes from R3, except the new field: it stays empty (even in PSA), so there is no mapping problem...

Any ideas, 'caus i'm all out?

Answer:
check the datasource, field is perhaps flagged "hidden for BW" or "only known in user-exit"

Ch
(feedback, please, because if "hidden for bw", I though it would not show up in rsa3)
_________________
_
There are only 10 types of people in the world :
those who understand binary and those who don't.

Answer:
Ch,
these flags are not the cause of our problems: they are not set.

(think you are correct: if any of those 2 was set, the field wouldn't show up in the RSA3)

Answer:
I experienced the same thing. Couldn't explain it or why this worked but I replicated the datasource and reactivated the transfer rules and then the new field was recognized. Again, I can't explain why that worked because I'm sure I had done it once because the new field was listed in the transfer rules.

Just out of curiousity, what version of BW are you running? We saw this in a sandbox for 3.0B.

kt

Answer:
Hi all,

just heard from the customer ( iwasn't at his site at the moment of the problems) that the problem was solved : problems was ... that they were using different selections in the infopackage and rsa3!
And they didnt bother to check on document level, so they only noticed it after 3 days.

Anyway, thanks for the effort!
T.
Copyright ?2007 - 2008 www.jt77.com